Integrating sound level meter

Integrating sound level meter is not only a general sound level meter for measuring exponential time weighted sound level, but also an integral average sound level meter for measuring time average sound level and an integral sound level meter for measuring sound exposure. It can also measure cumulative percentage sound level (statistical sound level). It can be used for various industrial environmental noise measurement and environmental noise survey measurement, especially for noise spectrum analysis. It can be used to measure the sound level of environment, machinery, traffic, ship and other noise; it can be used in industrial environmental protection, construction, health, teaching and scientific research departments. Integral sound level meter often Multihead Weigher Machine has problems 1. After the instrument power is turned on, the display does not display. No battery or poor battery contact; 2. The power switch is damaged or the contact is poor. The sound level displayed is significantly low. Maybe the microphone or the front stage is damaged. You can replace the microphone or the front stage, or the connection between the front stage socket and the motherboard falls off. 3. Do not print check whether the connection indicator on the printer is on. If not, restart the instrument and printer. 4. Unable to communicate with computer: view the interface and try again. The microphone used in the integrated sound level meter is a kind of fine sensor, please do not collide to avoid damage to the diaphragm, and it should be put aside properly when it is not necessary. Artificial damage is not Automatic Weighing System covered by the warranty. Attention should be paid to the polarity of the battery or external power supply of the device. Do not reverse connect the battery. When the instrument is not in use temporarily, the battery should be removed to avoid liquid leakage and damage the instrument. The instrument should be prevented from being placed in the center of low temperature, humidity, sewage, dust and air or chemical gas with high content of hydrochloric acid and alkali, so as to prevent direct sunlight. Please do not assemble the instrument without permission. If the instrument task is abnormal, it can be sent to the repair unit or factory for maintenance. Unauthorized assembly is not covered by the warranty.

评论

此博客中的热门博文

Explosion-proof vacuum cleaner for dust Application characteristics

Biometric Door Lock System

Access Control Systems Manufacturers - How to Find the Right Control System for Your Needs